CAD (0)
▾
Control/Signal Line HEMP Filters Standard Performance
HEMP Filters Power, Control, and Signal Lines
- Voltage Rating : 48 VDC or 120 VAC @ 0-60 Hz
- Visual/Mechanical : Per MIL-PRF-15733, paragraph 4.6.1
- Capacitance : Per MIL-STD-202, Method 305 @ 1 kHz
- Insulation Resistance : Per MIL-PRF-15733, paragraph 4.6.7 with Hemp Protection Module removed.
- Dielectric Withstanding Voltage : Per MIL-PRF-15733, paragraph 4.6.5 with Hemp Protection Module removed.
- Standard Insertion Loss : Per MIL-STD-220, 20 dB @ 10 kHz, 80 dB @ 10 MHz to 10 GHz
- Terminal Strength : Per MIL-PRF-15733, paragraph 4.6.11
- Voltage Discharge : Discharge to less than 30 Volts within 2 seconds after removal of power
- Terminals : 1/4" Quick Connect Tab
- Operating Temperature : -55 ºC to +71 ºC
- Storage Temperature : -55 ºC to +105 ºC
- Chassis & Terminal Finish : Electro Tin-Lead
- Chassis Material : 20 GA. Cold Rolled Steel
Unit of Measure
Items |
/Asset/a1108.jpg A-10356 1/2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance |
/Asset/a1108.jpg A-10357 2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance |
/Asset/a1108.jpg A-10358 5 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance |
/Asset/a1108.jpg A-10360 1/2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance |
/Asset/a1108.jpg A-10361 2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance |
|||||
Description |
N/A
|
|||||||||
Brands | N/A Captor | |||||||||
Voltage Rating (DC) | N/A 48 V @ 0 to 60 Hz | N/A 48 V @ 0 to 60 Hz | N/A 48 V @ 0 to 60 Hz | N/A | N/A | |||||
Voltage Rating (AC) | N/A | N/A | N/A | N/A 120 V @ 0 to 60 Hz | N/A 120 V @ 0 to 60 Hz | |||||
Frequency | N/A 0 to 60 Hz | |||||||||
Current | N/A 1/2 A | N/A 2 A | N/A 5 A | N/A 1/2 A | N/A 2 A | |||||
Insertion Loss Curve |
N/A
Curve 1, Minimum Insertion Loss |
|||||||||
High-Altitude Electromagnetic Pulse (HEMP) Residual | N/A < 0.1 A | N/A < 0.1 A | N/A < 0.1 A | N/A < 1 A | N/A < 1 A | |||||
Major Dimension A | N/A 6.90 in | N/A 6.90 in | N/A 8.40 in | N/A 6.40 in | N/A 6.40 in | |||||
Major Dimension B | N/A 4.50 in | N/A 4.50 in | N/A 6.00 in | N/A 4.00 in | N/A 4.00 in | |||||
Major Dimension C | N/A 1.25 in | N/A 1.50 in | N/A 2.00 in | N/A 1.25 in | N/A 1.25 in | |||||
Major Dimension D | N/A 2.50 in | N/A 2.50 in | N/A 3.00 in | N/A 2.50 in | N/A 2.50 in | |||||
Visual/Mechanical | N/A Per MIL-PRF-15733, Paragraph 4.6.1 | |||||||||
Capacitance | N/A Per MIL-STD-202, Method 305 @ 1 kHz | |||||||||
Insulation Resistance | N/A Per MIL-PRF-15733, Paragraph 4.6.7 with HEMP Protection Module Removed | |||||||||
Dielectric Withstanding Voltage | N/A Per MIL-PRF-15733, Paragraph 4.6.5 with HEMP Protection Module Removed | |||||||||
Standard Insertion Loss | N/A Per MIL-STD-220, 20 dB @ 10 kHz, 80 dB @ 10 MHz to 10 GHz | |||||||||
Terminal Strength | N/A Per MIL-PRF-15733, Paragraph 4.6.11 | |||||||||
Voltage Discharge | N/A Discharge to less than 30 Volts within 2 seconds after removal of power | |||||||||
Quick Connect Tab Terminals | N/A 1/4 in | |||||||||
Operating Temperature | N/A -55 to +71 ºC | |||||||||
Storage Temperature | N/A -55 to +105 ºC | |||||||||
Chassis & Terminal Finish | N/A Electro Tin-Lead | |||||||||
Chassis Material | N/A Cold Rolled Steel (CRS) | |||||||||
Chassis Material Thickness | N/A 20 gauge | |||||||||
Minimum Insertion Loss | N/A 20 dB @ 10 kHz 40 dB @ 100 kHz 60 dB @ 1 MHz 80 dB @ 10 MHz to 10 GHz | |||||||||
Compliance | N/A MIL-STD-188-125-1 MIL-STD-188-125-2 | |||||||||
Features |
N/A
|
|||||||||
Note | N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). | N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). | N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). |
N/A
For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A) For 120 VAC units only, compliance to E2 increases overall dimension "A" by 2.5 inches. |
N/A
For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A) For 120 VAC units only, compliance to E2 increases overall dimension "A" by 2.5 inches. |
|||||
|