CAD (0)
  • Cart is empty
  • Voltage Rating : 48 VDC or 120 VAC @ 0-60 Hz
  • Visual/Mechanical : Per MIL-PRF-15733, paragraph 4.6.1
  • Capacitance : Per MIL-STD-202, Method 305 @ 1 kHz
  • Insulation Resistance : Per MIL-PRF-15733, paragraph 4.6.7 with Hemp Protection Module removed.
  • Dielectric Withstanding Voltage : Per MIL-PRF-15733, paragraph 4.6.5 with Hemp Protection Module removed.
  • Standard Insertion Loss : Per MIL-STD-220, 20 dB @ 10 kHz, 80 dB @ 10 MHz to 10 GHz
  • Terminal Strength : Per MIL-PRF-15733, paragraph 4.6.11
  • Voltage Discharge : Discharge to less than 30 Volts within 2 seconds after removal of power
  • Terminals : 1/4" Quick Connect Tab
  • Operating Temperature : -55 ºC to +71 ºC
  • Storage Temperature : -55 ºC to +105 ºC
  • Chassis & Terminal Finish : Electro Tin-Lead
  • Chassis Material : 20 GA. Cold Rolled Steel
Unit of Measure
Items
Control/Signal Line HEMP Filters Standard/High Performance

1/2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance

Control/Signal Line HEMP Filters Standard/High Performance

2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance

Control/Signal Line HEMP Filters Standard/High Performance

5 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance

Control/Signal Line HEMP Filters Standard/High Performance

1/2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance

Control/Signal Line HEMP Filters Standard/High Performance

2 Ampere (A) Current Control/Signal Line HEMP Filter Standard Performance
Description N/A
  • Voltage Rating : 48 VDC or 120 VAC @ 0-60 Hz
  • Visual/Mechanical : Per MIL-PRF-15733, paragraph 4.6.1
  • Capacitance : Per MIL-STD-202, Method 305 @ 1 kHz
  • Insulation Resistance : Per MIL-PRF-15733, paragraph 4.6.7 with Hemp Protection Module removed.
  • Dielectric Withstanding Voltage : Per MIL-PRF-15733, paragraph 4.6.5 with Hemp Protection Module removed.
  • Standard Insertion Loss : Per MIL-STD-220, 20 dB @ 10 kHz, 80 dB @ 10 MHz to 10 GHz
  • Terminal Strength : Per MIL-PRF-15733, paragraph 4.6.11
  • Voltage Discharge : Discharge to less than 30 Volts within 2 seconds after removal of power
  • Terminals : 1/4" Quick Connect Tab
  • Operating Temperature : -55 ºC to +71 ºC
  • Storage Temperature : -55 ºC to +105 ºC
  • Chassis & Terminal Finish : Electro Tin-Lead
  • Chassis Material : 20 GA. Cold Rolled Steel
Brands N/A Captor
Voltage Rating (DC) N/A 48 V @ 0 to 60 Hz N/A 48 V @ 0 to 60 Hz N/A 48 V @ 0 to 60 Hz N/A N/A
Voltage Rating (AC) N/A N/A N/A N/A 120 V @ 0 to 60 Hz N/A 120 V @ 0 to 60 Hz
Frequency N/A 0 to 60 Hz
Current N/A 1/2 A N/A 2 A N/A 5 A N/A 1/2 A N/A 2 A
Insertion Loss Curve N/A
Curve 1, Minimum Insertion Loss
High-Altitude Electromagnetic Pulse (HEMP) Residual N/A < 0.1 A N/A < 0.1 A N/A < 0.1 A N/A < 1 A N/A < 1 A
Major Dimension A N/A 6.90 in N/A 6.90 in N/A 8.40 in N/A 6.40 in N/A 6.40 in
Major Dimension B N/A 4.50 in N/A 4.50 in N/A 6.00 in N/A 4.00 in N/A 4.00 in
Major Dimension C N/A 1.25 in N/A 1.50 in N/A 2.00 in N/A 1.25 in N/A 1.25 in
Major Dimension D N/A 2.50 in N/A 2.50 in N/A 3.00 in N/A 2.50 in N/A 2.50 in
Visual/Mechanical N/A Per MIL-PRF-15733, Paragraph 4.6.1
Capacitance N/A Per MIL-STD-202, Method 305 @ 1 kHz
Insulation Resistance N/A Per MIL-PRF-15733, Paragraph 4.6.7 with HEMP Protection Module Removed
Dielectric Withstanding Voltage N/A Per MIL-PRF-15733, Paragraph 4.6.5 with HEMP Protection Module Removed
Standard Insertion Loss N/A Per MIL-STD-220, 20 dB @ 10 kHz, 80 dB @ 10 MHz to 10 GHz
Terminal Strength N/A Per MIL-PRF-15733, Paragraph 4.6.11
Voltage Discharge N/A Discharge to less than 30 Volts within 2 seconds after removal of power
Quick Connect Tab Terminals N/A 1/4 in
Operating Temperature N/A -55 to +71 ºC
Storage Temperature N/A -55 to +105 ºC
Chassis & Terminal Finish N/A Electro Tin-Lead
Chassis Material N/A Cold Rolled Steel (CRS)
Chassis Material Thickness N/A 20 gauge
Minimum Insertion Loss N/A 20 dB @ 10 kHz 40 dB @ 100 kHz 60 dB @ 1 MHz 80 dB @ 10 MHz to 10 GHz
Compliance N/A MIL-STD-188-125-1 MIL-STD-188-125-2
Features N/A
  • Inductive Input.
  • Individually Filtered Lines.
  • Standard Performance and High Performance Insertion Loss Versions.
  • Captor can Supply Enclosures Holding Multiple Filters.
  • Field Replaceable HEMP Protection Module.
  • Custom Options Available.
Note N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A). N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A)
For 120 VAC units only, compliance to E2 increases overall dimension "A" by 2.5 inches.
N/A For compliance to E2 (intermediate pulse) add an "A" to the end of the part number (A-10356A)
For 120 VAC units only, compliance to E2 increases overall dimension "A" by 2.5 inches.