Voltage Rating (AC)
|
N/A
120 V @ 0 to 60 Hz 250 V @ 0 to 60 Hz
|
Frequency
|
N/A
0 to 60 Hz
|
Current
|
N/A
5 A
|
Insertion Loss Curve
|
N/A
Minimum Insertion Loss Curve, 100 dB at 14 kHz to 10 GHz
|
Leakage Current
|
N/A
< 0.9 A
|
Input Connection
|
N/A
D38999/20WE6PN
|
Output Connection
|
N/A
8-32 Stud Assemblies
|
Visual/Mechanical
|
N/A
Per MIL-PRF-15733, Paragraph 4.6.1
|
Capacitance
|
N/A
Per MIL-STD-202, Method 305 @ 1 kHz
|
Insulation Resistance
|
N/A
1500 MΩ minimum per MIL-STD-202, Method 302
|
Dielectric Withstanding Voltage
|
N/A
800 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301
|
Insertion Loss
|
N/A
Per MIL-STD-220, 100 dB @ 14 kHz to 10 GHz
|
Voltage Drop
|
N/A
Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
|
Terminal Strength
|
N/A
Per MIL-PRF-15733, Paragraph 4.6.11
|
Voltage Discharge
|
N/A
Discharge to Less than 30 Volts within 30 s After Removal of Power
|
Threaded Terminals
|
N/A
8-32 UNC-2A
|
Threaded Inserts
|
N/A
8-32 UNC-2B
|
Operating Temperature
|
N/A
-55 to +71 ºC
|
Storage Temperature
|
N/A
-55 to +105 ºC
|