Items |
A-6340 2.5 Amp Standard Model Tempest Filters |
A-6340A 2.5 Amp Standard Model Tempest Filters |
A-6345 5.0 Amp Standard Model Tempest Filters |
A-6345A 5.0 Amp Standard Model Tempest Filters |
A-6350 10.0 Amp Standard Model Tempest Filters |
|||||
Voltage Rating | N/A 120/230 VAC @ 60 Hz | |||||||||
Visual/Mechanical | N/A Per MIL-F-15733, Paragraph 4.6.1 | |||||||||
Capacitance | N/A Per MIL-STD-202, Method 305 @ 1 kHz | |||||||||
Insulation Resistance | N/A 1500 MΩ minimum per MIL-STD-202, Method 302 (prior to installation of bleeder resistors) | |||||||||
Dielectric Withstanding Voltage | N/A 1000 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301 | |||||||||
Insertion Loss | N/A Per MIL-STD 220 | |||||||||
Voltage Drop | N/A Less than 1% of rated voltage per paragraph 4.6.8 of MIL-F-15733 | |||||||||
Terminal Strength | N/A Per MIL-STD-202, method 211 | |||||||||
Leakage Current | N/A 5 mA maximum, measured per UL standard 1283 at 120 VAC, 60 Hz | |||||||||
Voltage Discharge | N/A Unit shall discharge to less than 30 VDC after removal or power | |||||||||
Operating Temperature | N/A -55 to +71 ÂșC | |||||||||
Fig. |
N/A
1 |
N/A
2 |
N/A
1 |
N/A
2 |
N/A
1 |
|||||
Current Rating | N/A 2.5 A | N/A 2.5 A | N/A 5 A | N/A 5 A | N/A 10 A | |||||
Dimension A | N/A 4.25 in | N/A 4.25 in | N/A 4.75 in | N/A 4.75 in | N/A 6.00 in | |||||
Dimension B | N/A 3.25 in | N/A 3.25 in | N/A 4.00 in | N/A 4.00 in | N/A 4.00 in | |||||
Dimension C | N/A 2.00 in | N/A 2.00 in | N/A 2.25 in | N/A 2.25 in | N/A 2.5 in | |||||
Input Connection | N/A IEC | N/A J1 | N/A IEC | N/A J1 | N/A IEC | |||||
Output Connection | N/A Solder Terminals | |||||||||
Insertion Loss Curve |
N/A
Insertion Loss Curve Figure 5 |
N/A
Insertion Loss Curve Figure 5 |
N/A
Insertion Loss Curve Figure 5 |
N/A
Insertion Loss Curve Figure 5 |
N/A
Insertion Loss Curve Figure 6 |
|||||
Note | N/A | N/A J1 is connector part number D38999/20WE6PN. | N/A | N/A J1 is connector part number D38999/20WE6PN. | N/A | |||||
|