Print Back
  • Voltage Rating : 120/250 VAC @ 0-60 Hz
  • Visual/Mechanical : Per MIL-PRF-15733, paragraph 4.6.1
  • Capacitance : Per MIL-STD-202, Method 305 @ 1 kHz
  • Insulation Resistance : 1500 MΩ minimum per MIL-STD-202, Method 302
  • Dielectric Withstanding Voltage : 800 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301
  • Insertion Loss : Per MIL-STD-220,100 dB @ 14 kHz to 10 GHz
  • Voltage Drop : Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
  • Terminal Strength : Per MIL-PRF-15733 Paragraph 4.6.11
  • Voltage Discharge : Discharge to less than 30 Volts within 30 s after removal of power
  • Threaded Terminals : 8-32 UNC-2A
  • Threaded Inserts : 8-32 UNC-2B
  • Operating Temperature : -55 ºC to+71 ºC
  • Storage Temperature : -55 ºC to +105 ºC
  • Chassis & Terminal Finish : Electro Tin-Lead
  • Chassis Material : CRS
High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
Dimensional Drawing for High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
Unit of Measure
Items High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
A-10301
2.5 Ampere (A) Current High Performance TEMPEST Filter
High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
A-10302
5 Ampere (A) Current High Performance TEMPEST Filter
High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
A-10303
10 Ampere (A) Current High Performance TEMPEST Filter
High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
A-10304
15 Ampere (A) Current High Performance TEMPEST Filter
High Performance TEMPEST Filters with High-Altitude Electromagnetic Pulse (HEMP) Protection Option
A-10305
20 Ampere (A) Current High Performance TEMPEST Filter
Voltage Rating (AC) N/A 120 V @ 0 to 60 Hz 250 V @ 0 to 60 Hz
Frequency N/A 0 to 60 Hz
Current N/A 2.5 A N/A 5 A N/A 10 A N/A 15 A N/A 20 A
Insertion Loss Curve N/A
Minimum Insertion Loss Curve, 100 dB at 14 kHz to 10 GHz
Major Dimension A N/A 5.75 in N/A 6.75 in N/A 8.00 in N/A 7.25 in N/A 8.25 in
Major Dimension B N/A 4.00 in N/A 4.00 in N/A 4.50 in N/A 6.00 in N/A 6.00 in
Major Dimension C N/A 2.25 in N/A 2.25 in N/A 3.00 in N/A 3.00 in N/A 4.00 in
Leakage Current N/A < 0.45 A N/A < 0.9 A N/A < 1.6 A N/A < 2.2 A N/A < 2.8 A
Input Connection N/A D38999/20WE6PN
Output Connection N/A 8-32 Stud Assemblies
Visual/Mechanical N/A Per MIL-PRF-15733, Paragraph 4.6.1
Capacitance N/A Per MIL-STD-202, Method 305 @ 1 kHz
Insulation Resistance N/A 1500 MΩ minimum per MIL-STD-202, Method 302
Dielectric Withstanding Voltage N/A 800 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301
Insertion Loss N/A Per MIL-STD-220, 100 dB @ 14 kHz to 10 GHz
Voltage Drop N/A Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
Terminal Strength N/A Per MIL-PRF-15733, Paragraph 4.6.11
Voltage Discharge N/A Discharge to Less than 30 Volts within 30 s After Removal of Power
Threaded Terminals N/A 8-32 UNC-2A
Threaded Inserts N/A 8-32 UNC-2B
Operating Temperature N/A -55 to +71 ºC
Storage Temperature N/A -55 to +105 ºC
Chassis & Terminal Finish N/A Electro Tin-Lead
Chassis Material N/A Cold Rolled Steel (CRS)
Features N/A
  • Individually Filtered Lines.
  • High Performance TEMPEST Filters.
  • Alternate Mounting Means Available.
  • Captor can Supply Enclosure Housing with Multiple Filters.
  • Custom Options Available.
Note N/A Specifications subject to change.