Print Back
If your system has MIL-STD-461 compliance requirements, many of the DC-DC converters on the market will not be compliant. The EMI filters listed below have been designed to meet this requirement. In addition, custom voltages/current ratings/size can be designed to meet your specific application.
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Dimensional Drawing for Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Unit of Measure
Items Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
A-10311
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
A-10312
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
A-10313
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
A-10314
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
A-10315
Circuit Card Assembly (CCA) Mounted Electromagnetic Interference (EMI) Filters
Voltage Rating (DC) N/A 28 V
Current N/A 1 A N/A 2 A N/A 5 A N/A 10 A N/A 15 A
Insertion Loss Curve N/A
Typical Insertion Loss Curve - 1
Size N/A
Size - 1
Weight N/A ~38 g
Case Material N/A Polycarbonate
Visual/Mechanical N/A Per MIL-PRF-15733, Paragraph 4.6.1
Insulation Resistance N/A 10 MΩ minimum line-to-line & line-to-chassis per MIL-STD-202, Method 302
Dielectric Withstanding Voltage N/A 100 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301
Insertion Loss N/A Per MIL-STD-220, see graphs
Terminal Strength N/A Per MIL-PRF-15733
Operating Temperature N/A -55 to +95 ºC
Storage Temperature N/A -55 to +105 ºC
Soldering N/A In accordance with J-STD-001 Class 3