• Compact, space-saving configurations offering high power performance
  • Superior isolation achieved by utilizing Captor feedthru capacitors
  • Demanding Tempest Requirements? STOP YOUR SEARCH and contact Captor
  • Voltage Rating : 120/230 VAC @ 60 Hz
  • Visual/Mechanical : Per MIL-F-1
  • more
Unit of Measure

Specifications

Voltage Rating

120/230 VAC @ 60 Hz

Visual/Mechanical

Per MIL-F-15733, Paragraph 4.6.1

Capacitance

Per MIL-STD-202, Method 305 @ 1 kHz

Insulation Resistance

1500 MΩ minimum per MIL-STD-202, Method 302 (prior to installation of bleeder resistors)

Dielectric Withstanding Voltage

1000 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301

Insertion Loss

Per MIL-STD 220

Voltage Drop

Less than 1% of rated voltage per paragraph 4.6.8 of MIL-F-15733

Terminal Strength

Per MIL-STD-202, method 211

Leakage Current

5 mA maximum, measured per UL standard 1283 at 120 VAC, 60 Hz

Voltage Discharge

Unit shall discharge to less than 30 VDC after removal or power

Operating Temperature

-55 to +71 ºC

Fig.


4

Current Rating

20 A

Dimension A

9.00 in

Dimension B

6.00 in

Dimension C

4.00 in

Input Connection

J1

Output Connection

8-32UNC-2A Terms

Insertion Loss Curve

Insertion Loss Curve


Insertion Loss Curve Figure 6

Note

Note

J1 is connector part number D38999/20WE6PN.