CAD (0)
  • Cart is empty
  • Voltage : 0 to 480 Volts
  • Current : 0 to 100 Amps
  • Frequency : DC to 400 Hz
  • Insertion Loss : 100 dB minimum from 14 kHz to 10 GHz
  • Operating Temperature : -40 ºC to +71 ºC
  • Storage Temperature : -55 ºC to +105 ºC
  • Altitude : Maximum of 15,000 feet
  • Humidity : 10 to 90 Percent
  • Fungus : Non-nutritive materials are used
  • Corrosion : Hermetically sealed steel or aluminum enclosures with tin-lead plating
Unit of Measure

Specifications

Voltage

N/A 0 to 480 V

Operating Temperature

N/A -40 to +71 ºC

Storage Temperature

N/A -55 to +105 ºC

Maximum Altitude

N/A 15000 ft

Humidity

N/A 10 to 90 %

Fungus

N/A Non-nutritive materials are used

Corrosion

N/A Hermetically sealed steel or aluminum enclosures with tin-lead plating

Maximum Dimension A

N/A 8.90 in

Dimension B

N/A 6.50 in

Note

N/A With HEMP protection devices removed.
Full load from 100 KHz to 20 MHz.

Electrical Ratings

Voltage (Vrms)

N/A 35

Voltage (Peak)

N/A 50

Current

N/A 2 A

Frequency

N/A DC-60 Hertz

DCR

N/A ≤ 0.3 Ω

DWV (DC)

N/A 200 V

MIL-STD-220 Insertion Loss (Limit)

N/A 100 dB Minimum from 14 kHz through 10 GHz

PCI - HEMP Parameters

Type

N/A Short Pulse

Type of Injection

N/A Common Mode Wire-to-ground

Common Mode Peak Short- Circuit Current

N/A 5000 A

Wire-to-ground Peak Short- Circuit Current

N/A 2500 A

Common Mode Source Impedance

N/A ≥ 60 Ω

Wire-to-ground Source Impedance

N/A ≥ 60 Ω

Wire-to-ground Load Impedance

N/A 2 Ω

Common Mode Residual Peak Current

N/A ≤ 0.1 A

Wire-to-ground Residual Peak Current

N/A ≤ 0.1 A

Attributes/Options

Attributes/Options

N/A
  • Meet or exceed the MIL-STD-188-125-1 requirements
  • Inductive Input
  • Choice of Termination Configurations
    • Quick Disconnect Terminal Tabs
    • Threaded Studs
    • Connectors
  • Can be supplied with HEMP Protection Modules
  • Supplied with Certified PCI data upon request
  • Existing Designs for:
    • Other Power Lines (Intersite)
    • Audio/Data Lines (Intersite)
    • Control/Signal Lines (Intersite)
  • Existing Applications include:
    • AC/DC power
    • Telephone Lines
    • Analog Fire Alarms
    • Servo Motors
    • Synchro Transmitter
  • Custom tailoring for your unique application