Specifications
- Voltage Rating: 277/480 VAC @ 60 Hz
- Current Rating: 50 through 800 Amperes
- Insulation Resistance: Per MIL-PRF-15733, prior to discharge resistor installation.
- Dielectric Withstanding Voltage: 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to installation of discharge resistor
- Voltage Drop: Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733
- Voltage Discharge: Discharge to less than 30 Volts within 30s after removal of power
- Operating Temperature: -40° C to +65° C
- Storage Temperature: -55° C to +105° C
- Insertion Loss: Measured per MIL-STD-220
- Modified: NEMA 1 type enclosure
- Cabinet Material: Stainless Steel construction
- Filter insert case material: Cold rolled steel construction with a corrosion resistant plating
- Epoxy paint optional
- Shielding effectiveness measured on clean side greater than 100 dB from 14KHz or 100KHz to 10 GHz
- Dual removable access covers
Unit of Measure
| Items |
/Asset/Shielded-Facility-Room-Power-Line-Filters.jpg A-11030-2 2 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter |
/Asset/Shielded-Facility-Room-Power-Line-Filters.jpg A-11030-3 3 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter |
/Asset/Shielded-Facility-Room-Power-Line-Filters.jpg A-11030-4 4 Line 50 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter |
/Asset/Shielded-Facility-Room-Power-Line-Filters.jpg A-11031-2 2 Line 100 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter |
/Asset/Shielded-Facility-Room-Power-Line-Filters.jpg A-11031-3 3 Line 100 Ampere (A) Current Rating High Performance Shielded Facility Room Power Line Filter |
|||||
| Description | N/A 100dB, 14KHz to 1 GHz measured per MIL-STD-220, 50ohms system 10 to 100% load current | |||||||||
| Brands | N/A Captor | |||||||||
| Alternating Current (AC) Voltage at 60 Hertz (Hz) | N/A 270 V480 V | |||||||||
| Insulation Resistance | N/A Per MIL-PRF-15733, prior to discharge resistor installation. | |||||||||
| Dielectric Withstanding Voltage | N/A 2250 VDC line-to-chassis per MIL-STD-202, Method 301 prior to installation of discharge resistor | |||||||||
| Voltage Drop | N/A Less than 1% of rated voltage per paragraph 4.6.8 of MIL-PRF-15733 | |||||||||
| Voltage Discharge | N/A Discharge to less than 30 Volts within 30s after removal of power | |||||||||
| Operating Temperature | N/A -40 to +65 ºC | |||||||||
| Storage Temperature | N/A -55 to +105 ºC | |||||||||
| Insertion Loss | N/A Measured per MIL-STD-220 | |||||||||
| Filter Type | N/A High Performance Filter | |||||||||
| Number of Lines | N/A 2 | N/A 3 | N/A 4 | N/A 2 | N/A 3 | |||||
| Current Rating | N/A 50 A | N/A 50 A | N/A 50 A | N/A 100 A | N/A 100 A | |||||
| Size A | N/A 13.0 in | N/A 19.0 in | N/A 25.0 in | N/A 15.0 in | N/A 21.0 in | |||||
| Size B | N/A 28.0 in | N/A 28.0 in | N/A 28.0 in | N/A 32.0 in | N/A 32.0 in | |||||
| Size C | N/A 7.0 in | |||||||||
| Size D | N/A 18.0 in | N/A 18.0 in | N/A 18.0 in | N/A 22.0 in | N/A 22.0 in | |||||
| Size E | N/A 14.0 in | N/A 20.0 in | N/A 26.0 in | N/A 16.0 in | N/A 22.0 in | |||||
| Estimated Weight | N/A 110 lb | N/A 175 lb | N/A 230 lb | N/A 180 lb | N/A 280 lb | |||||
| Enclosure |
N/A
|
|||||||||
| Note |
N/A
When installed with best grounding practice, additional shielding and Isolation between input and output compartments Specifications subject to change Cabinet Supplied with Filter Inserts, 50 to 800 Amps 2, 3 and 4 Power Line filters Installed |
|||||||||
|
|
||||||||||