CAD (0)
  • Cart is empty
Captor Corporation is pleased to introduce a new series of COTS DC and AC single and three phase (Delta and Wye) power line filters for MIL-STD-461 Applications. The COTS Filters are designed to mitigate conducted emissions as specified in the MIL-STD-461 CE102 requirement from 10KHZ to 10MHz. Feed-Through (line to ground) capacitors are incorporated in the filter assemblies to maintain filter attenuation up to 1GHZ and above when installed with additional shielding to isolate input and output compartments.

These filters comply with the electrical requirements and meet the maximum capacitance to ground limits for 50Hz and 400Hz power line frequencies per MIL-STD-461 for Navy applications. The filter mechanical constructions and encapsulated assemblies will withstand the stringent environmental requirements and conditions of all air, sea and ground applications. COTS filter assemblies can also be supplied with Metal Oxide Varistors, circuit breakers and military connectors for I/O connections upon request to comply with system level requirements.
Unit of Measure
Items
COTS MIL-STD-461 Single Phase EMI Filters

5 Ampere (A) Current COTS MIL-STD-461 Single Phase EMI Filter

COTS MIL-STD-461 Single Phase EMI Filters

15 Ampere (A) Current COTS MIL-STD-461 Single Phase EMI Filter

COTS MIL-STD-461 Single Phase EMI Filters

30 Ampere (A) Current COTS MIL-STD-461 Single Phase EMI Filter

COTS MIL-STD-461 Single Phase EMI Filters

50 Ampere (A) Current COTS MIL-STD-461 Single Phase EMI Filter
Description N/A Captor Corporation is pleased to introduce a new series of COTS DC and AC single and three phase (Delta and Wye) power line filters for MIL-STD-461 Applications. The COTS Filters are designed to mitigate conducted emissions as specified in the MIL-STD-461 CE102 requirement from 10KHZ to 10MHz. Feed-Through (line to ground) capacitors are incorporated in the filter assemblies to maintain filter attenuation up to 1GHZ and above when installed with additional shielding to isolate input and output compartments.

These filters comply with the electrical requirements and meet the maximum capacitance to ground limits for 50Hz and 400Hz power line frequencies per MIL-STD-461 for Navy applications. The filter mechanical constructions and encapsulated assemblies will withstand the stringent environmental requirements and conditions of all air, sea and ground applications. COTS filter assemblies can also be supplied with Metal Oxide Varistors, circuit breakers and military connectors for I/O connections upon request to comply with system level requirements.
Brands N/A Captor
Compliance N/A MIL-STD-461
Phase N/A 1
Alternating Current (AC) Voltage N/A 250 V
Frequency N/A 50 to 400 Hz
Direct Current (DC) Voltage N/A 600 V
Current N/A 5 A N/A 15 A N/A 30 A N/A 50 A
Terminals N/A 10-32 N/A 10-32 N/A 10-32 N/A 1/4-20
Dimension L N/A 6.50 in N/A 6.50 in N/A 7.00 in N/A 7.00 in
Dimension W N/A 2.50 in N/A 2.50 in N/A 3.00 in N/A 3.00 in
Dimension H N/A 2.50 in N/A 2.50 in N/A 2.75 in N/A 2.75 in
Dimension D N/A 3.75 in N/A 3.75 in N/A 4.25 in N/A 4.25 in
Dimension E N/A 5.00 in N/A 5.00 in N/A 5.50 in N/A 5.50 in
Dimension F N/A 3.13 in N/A 3.13 in N/A 3.63 in N/A 3.63 in
Additional Information N/A Captor Offers:
  • Extensive EMI/HEMP filter design, development and manufacturing
  • Terminated cable assemblies for MIL applications
  • Power line filters that comply with all applicable military/industrial/commercial standards
  • Technical support during initial product design and development
  • In house environmental test capabilities
Captor is:
  • AS9100D including ISO 9000:2015 certified
  • Certified to IPC 610, IPC-620 and J-STD-001
Note N/A For 400Hz add an A to the end of the part number.

Specifications are subject to change without notice. Specifications are typical and may not apply to all applications.